Product introduction
Wuhan UHV Power Technology Co.,Ltd., is a professional manufacturer and supplier of high-voltage power testing equipment in China.The ground resistance measuring instrument is a new type of ground resistance measuring instrument, which combines the three-end button and four-end button measuring methods by using advanced medium and large scale integrated circuit instead of the traditional manual manual power generation.
The working principle is that the DC/AC converter in the machine changes DC into low-frequency constant current of AC, and the circuit is formed by auxiliary ground electrode C and measured object E, which generates AC voltage drop on the measured object, and is fed into AC amplifier for amplification through auxiliary ground electrode P, and then sent to the meter head for display through detection. With the aid of multiplying power switch, three different quantity limit can be obtained: 0 ~ 2 Ω, 0 ~ 20 Ω, 0 ~ 200 Ω.
The earth resistance measuring instrument is suitable for measuring the earth resistance of various devices and the conductor resistance value of low resistance in electric power, post and telecommunication, railway, communication, mining and other departments. The table also measures soil resistivity and ground voltage.
![]() | ![]() | ![]() |
Production functions
Ground resistance measurement — Measures the ground resistance of grounding systems and grounding electrodes. Core measurement function with a range of 0 to 200Ω.
Low resistance measurement — Measures the resistance of low-resistance conductors.
Soil resistivity measurement — Used for measuring soil resistivity, applicable to grounding system design and grounding performance evaluation.
AC voltage measurement — Measures on-site AC / power frequency voltage with a range of 0 to 19.99V, assisting in evaluating power frequency interference at the grounding test site.
Parameter teknik
| Kondisi | Suhu lingkungan | 0℃~+45℃ |
| Kelembapan relatif | ≤85% RH | |
| Rentang pengukuran dan arus konstan (RMS)) | Perlawanan | 0~2Ω(10mA),2~20Ω(10mA),20~200Ω(1mA) |
| Tegangan | AC0~19.99V | |
| Akurasi dan resolusi pengukuran | Presisi | 0~0,2Ω≤±3%±1 hari |
| 0,2Ω~199,9Ω≤±1,5%±1 hari | ||
| 1~19,99V≤±3%±1 hari | ||
| Resolusi | 0,001Ω、0,01Ω、0,1Ω、0,01V | |
Kesalahan pengukuran disebabkan oleh alat bantu tahanan pentanahan dan tegangan tanah | Izinkan resistensi grounding tambahan | RC (Antara C1 dan C2) |
| 0~2Ω,2~20Ω≤1kΩ | ||
| 20~200Ω≤2kΩ | ||
| RP (Antara P1 dan P2) <40kΩ,kesalahan≤±5% | ||
Tegangan ground yang diijinkan (efektif nilai frekuensi daya) | ≤5V, kesalahan≤±5% | |
| Konsumsi daya dan daya | Kehilangan daya maksimum | ≤2W |
| DC | Baterai 8×1.5V(AA,R6). | |
| AC | 220V/50Hz | |
| Volume dan Berat | Ukuran | 220×200×105mm3 |
| Berat | ≤1,4kg |
Tidak adaknama:Pengukur Resistansi Tanah; Earth Resistance Mete
Fitur
1、Alat ukur tahanan pentanahan dibuat dengan paduan aluminium berkekuatan tinggi sebagai casingnya. Untuk mencegah frekuensi industri dan gangguan rf, mode pelacakan dan deteksi sinkron loop terkunci fase diadopsi di sirkuit, dan filter kapasitor sakelar dilengkapi untuk membuat instrumen memiliki kemampuan anti-interferensi yang lebih baik.
2、Teknologi konversi DC/AC diadopsi untuk mengubah DC menjadi arus konstan frekuensi rendah AC untuk memudahkan pengukuran.
3、 Izinkan resistensi grounding tambahan 0 ~ 1,8kOh(RC), 0 ~ 40KOh(RP) tidak mempengaruhi hasil pengukuran.
4、Alat ukur resistansi grounding tidak memerlukan penyesuaian dan keseimbangan manual, layar LCD posisi 3(1/2), selain mengukur resistansi bumi, namun juga dapat mengukur resistansi konduktor resistansi rendah, resistivitas tanah, dan tegangan ac. Jika rangkaian pengujian tidak menampilkan &ldquo di header; 1 & seluruh; Singkatan dari overflow, sejalan dengan kebiasaan pengukuran konvensional.
Application Scenarios
Substation grounding system testing
Used for testing the grounding resistance of grounding grids and grounding devices in substations and distribution stations.
Power equipment grounding testing
Used for grounding performance testing of electrical equipment such as transformers, switchgear, distribution cabinets, and motors.
Lightning protection grounding testing
Used for grounding resistance testing of lightning protection devices on buildings, equipment rooms, communication facilities, and other structures.
Building grounding system testing
Used for grounding system testing of factories, office buildings, residential buildings, and large structures.
Communication base station grounding testing
Used for grounding resistance testing of facilities such as communication base stations and communication rooms.
New energy power plant grounding testing
Used for grounding system testing of photovoltaic power plants, wind farms, energy storage power stations, and similar facilities.
Grounding system construction acceptance
After completion of new grounding systems, used to measure grounding resistance and determine whether design requirements have been met.
Grounding system operation and maintenance inspection
Used for regular grounding resistance testing in power, telecommunications, industrial enterprises, and other facilities to identify abnormal grounding performance.
Soil resistivity testing
Before constructing a grounding system, used to measure on-site soil resistivity, providing a basis for the design of grounding electrodes and grounding grids.
Frequently Asked Questions
Q:Is the tester suitable for electrical environments with interference?A:Yes. The tester uses filtering and phase-locked detection technology to improve resistance to power-frequency and RF interference.
Q:Does it require manual balancing before testing?
A:No. The instrument uses an automatic measurement and balancing system, which simplifies field operation.
Q:What applications is it suitable for?A:It is suitable for grounding tests in power systems, substations, buildings, lightning protection systems, communication base stations, industrial facilities, and renewable energy plants.